Easily To Pass New SolarWinds Hybrid-Cloud-Observability-Network-Monitoring Dumps with 152 Questions [Q52-Q71]

Share

Easily To Pass New SolarWinds Hybrid-Cloud-Observability-Network-Monitoring Dumps with 152 Questions

Latest Hybrid-Cloud-Observability-Network-Monitoring Study Guides 2026 - With Test Engine PDF

NEW QUESTION # 52
Which custom poller can display the poller results as a chart, gauge, or table?

  • A. network insight
  • B. universal device poller (UnDP)
  • C. device studio poller
  • D. hardware health

Answer: B


NEW QUESTION # 53
What is needed to edit trigger conditions in flow alerts?

  • A. PowerShel
  • B. Python
  • C. SQL
  • D. SVVQL

Answer: D


NEW QUESTION # 54
If an SNMP community string is changed on a device, which two of the following steps are required to re- establish successful polling on the node? (Choose two.)

  • A. Restart the SNMP service on the source device.
  • B. Edit the node properties and save the changes.
  • C. Delete and add the node back into the platform.
  • D. Update the community string in node properties.

Answer: B,D

Explanation:
Comprehensive and Detailed Explanation From Exact Extract:
When the SNMP community string is changed on a device, SolarWinds recommends:
Edit the node properties and save the changes.
Update the community string in node properties to match the new value on the device.
"To restore polling, edit the node in SolarWinds, update the SNMP community string in the properties, and save the changes. This ensures that SolarWinds can authenticate and resume polling. Deleting and re-adding the node is not necessary, nor is restarting the SNMP service on the device in most cases." References:
Network Performance Monitor Administrator Guide, Section: "SNMP Node Management" SolarWinds Success Center: "Updating SNMP Credentials"


NEW QUESTION # 55
When creating a new rule action, what is the best option to enable if too many events trigger the rule within a short time?

  • A. excessive event
  • B. time window
  • C. flood protection
  • D. entry count

Answer: C

Explanation:
Comprehensive and Detailed Explanation From Exact Extract:
In SolarWinds Log Analyzer and other log-based alerting systems, "flood protection" is a key feature to prevent alert storms when numerous events trigger a rule in a very short period. From the SolarWinds documentation:
"Flood protection ensures that if an excessive number of log entries match a rule in a short period, only a manageable number of actions are triggered, and the remainder are suppressed or summarized. This prevents overwhelming the system and users with repeated alerts." This is best practice for maintaining alert quality and system performance.
References:
Log Analyzer Administrator Guide, "Rule Actions and Flood Protection"


NEW QUESTION # 56
Which tool can be used to display the physical layout of interfaces on graphical stencils?

  • A. device studio
  • B. network insight
  • C. NetPath
  • D. device view

Answer: D

Explanation:
The "Device View" feature allows users to view the physical layout of device interfaces on graphical stencils, providing an intuitive graphical representation of port locations and status.
Exact Extract from Official Guide:
"Device View displays the physical layout of device interfaces using graphical stencils for supported devices."
- (Network Performance Monitor Administrator Guide, "Device View" section) References:
Network Performance Monitor Administrator Guide, Device View


NEW QUESTION # 57
Upon examining bandwidth utilization, it is confirmed that the total utilization and flow numbers do not match. What is the likely cause?

  • A. a firewall is blocking the data flow configuration
  • B. receivingboth IPv4 and IPv6 flows and not all are counted in total bandwidth
  • C. SNMP bandwidth numbers for the interface need to be adjusted in the console
  • D. flows do not contain all traffic in bandwidth numbers

Answer: D


NEW QUESTION # 58
Which additional polling method is needed after adding an F5 load balancing node for SNMP monitoring?

  • A. iControl
  • B. WM1
  • C. API
  • D. CLI

Answer: A


NEW QUESTION # 59
Which two of the following services can be monitored in network insight with network health, performance monitor, and NCM features installed in hybrid cloud observability? (Choose two.)

  • A. access lists
  • B. high availability details
  • C. policy details
  • D. global protect VPN

Answer: B,C

Explanation:
Comprehensive and Detailed Explanation From Exact Extract:
With Network Insight features (including for Palo Alto and F5 BIG-IP devices) installed alongside Network Configuration Manager and Performance Monitoring, you can monitor:
High availability details: Provides information on device redundancy, failover status, and clustering.
Policy details: Enables insight into firewall, security, and NAT policies for managed devices.
Access lists and VPNs may be monitored in other modules, but the primary, advanced insight is for high availability and policy configurations.
References:
NPM Administrator Guide: Network Insight Features and Monitored Services Network Insight for Palo Alto and F5 - Service and Policy Monitoring


NEW QUESTION # 60
It is taking longer than normal for a single mission critical node to poll for data. Where would the polling interval for the node be changed?

  • A. Node Details Summary > Resources > Memory
  • B. Settings > All Settings > Polling Settings
  • C. Settings > All Setting > Core Thresholds
  • D. Node Details Summary > Edit Node > Polling

Answer: D

Explanation:
Comprehensive and Detailed Explanation From Exact Extract:
To change the polling interval for a specific node, navigate to the Node Details Summary, then choose "Edit Node." In the polling section, you can configure how often SolarWinds polls this node for status and statistics. This is the correct place for per-node polling interval adjustments.
The global polling settings under "Settings > All Settings > Polling Settings" (option D) affect all nodes, not an individual node.
References:
NPM Administrator Guide: Changing Node-Specific Polling Intervals


NEW QUESTION # 61
The web console is showing the status of a network router as "down", however the node is up and running.
Which two of the following causes could be creating the issue? (Choose two.)

  • A. ICMP is blocked between the device and the polling engine
  • B. SNMP is blocked between the device and the polling engine
  • C. router is configured as a parent in a node dependency
  • D. agent connection status with the polling engine is "down'

Answer: A,B


NEW QUESTION # 62
What can be done to display the average CPU utilization of a node in a web console widget, if the device studio poller returns a table of multi-core CPU utilizations?

  • A. Configure the web console widget to calculate the average of the returned table values.
  • B. Contact the device vendor to provide an SNMP object ID (OID) for the average CPU utilization statistic.
  • C. Select the add calculated value option and use the average function for returned values.
  • D. Display the returned table of values in the web console widget and manually calculate the average.

Answer: C

Explanation:
Comprehensive and Detailed Explanation From Exact Extract:
When a device returns multi-core CPU statistics as a table, SolarWinds Device Studio allows you to use the
"Add Calculated Value" option and select the average function. This enables the web console widget to display the computed average CPU utilization automatically.
The documentation explains:
"For devices with multi-core CPUs, you can use the Add Calculated Value feature in the Device Studio to compute the average (or other statistical functions) of returned table values, which can then be visualized directly in widgets." References:
Network Performance Monitor Administrator Guide, "Device Studio Calculated Values" SolarWinds Success Center: "Averaging Table Poller Results"


NEW QUESTION # 63
In device studio, the test node being built for a new custom poller is returning four usage values for the CPU (one for each CPU core). If the goal is to have one value for the entire CPU, how can that be accomplished?

  • A. create a new calculated value to average the four individual values
  • B. there is not an object ID (OJD) for CPU usage, nothing can be done
  • C. device studio would not be the correct tool to use in this situation
  • D. values can be combined after the poller is created in poller settings

Answer: A

Explanation:
Comprehensive and Detailed Explanation From Exact Extract:
Device Studio allows you to define calculated values based on multiple polled results. To aggregate per-core CPU usage into a single metric, you can create a calculated value (such as the average) using the outputs from all cores.
From the documentation:
"Device Studio enables you to define calculated values (such as sum or average) when multiple SNMP values are returned, allowing you to represent a total or average CPU usage." References:
NPM Administrator Guide: Device Studio Calculated Values


NEW QUESTION # 64
Network wide node and interface changes were recently made to several fields including names and IP addresses on nodes, captions, and aliases for their interfaces. Those changes are not updated in the hybrid cloud observability web console, even if a new polling is forced.
What should be done to resolve the issue?

  • A. Run a rediscovery on both nodes and interfaces to refresh the data.
  • B. Manually update the changed information in each poller.
  • C. Delete and re-add each of the nodes and their interfaces.
  • D. Run a rediscovery on the node, which will also update the interfaces.

Answer: A


NEW QUESTION # 65
Which three of the following setting can be used to customize the thresholds for an object in SolarWinds' platform? (Choose three.)

  • A. X of Y polls
  • B. X concurrent polls
  • C. single poll
  • D. X consecutive polls

Answer: A,B,D


NEW QUESTION # 66
Which two of the following data sources can be used for polling devices in device studio? (Choose two.)

  • A. polled value by a device on an object ID
  • B. night and day standard deviation of calculated value
  • C. predicted value from OID baseline
  • D. calculated result from transformation of polled values

Answer: A,D


NEW QUESTION # 67
Which port allows log analysis in the SolarWinds platform to accept secure syslog messages?

  • A. UDP port 514
  • B. TCP port 601
  • C. UDP port 10514
  • D. TCP port 6514

Answer: D


NEW QUESTION # 68
A "no data" message is displayed in NetFlow charts. How can this be resolved?

  • A. Shorten the time for view and resource.
  • B. Refresh the current window.
  • C. Restart collector service.
  • D. Confirm account has viewing permissions.

Answer: C

Explanation:
Comprehensive and Detailed Explanation From Exact Extract:
A "no data" message in NetFlow charts usually indicates that the flow collector service is not receiving or processing flow data. One of the primary troubleshooting steps recommended in the SolarWinds documentation is to restart the collector service. This resolves issues caused by service interruptions, memory leaks, or flow processing errors.
The documentation states:
"If NetFlow charts display 'no data,' verify that the NetFlow collector service is running. Restart the collector service if necessary, as service interruptions can cause a lack of flow data display." References:
Network Performance Monitor Administrator Guide, "Troubleshooting NetFlow No Data Issues" SolarWinds Success Center: "NetFlow Collector Service Troubleshooting"


NEW QUESTION # 69
What is the default amount of historical data needed for calculating capacity forecast?

  • A. 7 to 180 days
  • B. 1 to 90 days
  • C. 1 to 30 days
  • D. 7 to 30 days

Answer: D

Explanation:
Comprehensive and Detailed Explanation From Exact Extract:
By default, SolarWinds Network Performance Monitor uses historical data from the last 7 to 30 days to calculate capacity forecasts. This range balances the need for relevant recent data with enough samples to provide trend accuracy.
The documentation states:
"Capacity forecasting in SolarWinds NPM uses the last 7 to 30 days of historical data by default for its projections." References:
NPM Administrator Guide: Capacity Forecast Calculations - Default Data Range


NEW QUESTION # 70
To drill down into a log summary for a specific node, where in SolarWinds' platform can a user view these logs?

  • A. Alerts and Activity > Message Center
  • B. My Dashboard > Logs > Log Viewer
  • C. Node Details Summary > Management > Analyze Logs
  • D. Node Details Summary > Management > List Resources

Answer: C

Explanation:
Comprehensive and Detailed Explanation From Exact Extract:
For a node-specific log view, navigate to the node's details summary and choose "Analyze Logs" under the Management section. This provides a filtered view of log messages for the selected node, allowing you to drill into relevant log events and details.
From the documentation:
"To view logs for a specific node, open Node Details > Management > Analyze Logs for node-level log analysis and troubleshooting." References:
Log Analyzer Administrator Guide: Viewing Node-Specific Logs


NEW QUESTION # 71
......

Hybrid-Cloud-Observability-Network-Monitoring Dumps and Exam Test Engine: https://examdumps.passcollection.com/Hybrid-Cloud-Observability-Network-Monitoring-valid-vce-dumps.html